  1. Results From The WOW.Com Content Network
  2. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.

  3. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    Earthing transformer with a zig-zag. Grounding transformers most commonly incorporate a single winding transformer with a zigzag winding configuration, but may also be created with a (rare case) delta-wye transformer. [2] [4] Neutral grounding transformers are very common on generators in power plants and wind farms. [2]

  4. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    A special form of auto transformer called a zig zag is used to provide grounding on three-phase systems that otherwise have no connection to ground. A zig-zag transformer provides a path for current that is common to all three phases (so-called zero sequence current).

  5. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral. To restrict the ground faults in such systems, we may use a zigzag wound transformer to create a neutral along with the ground fault relay.

  6. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the equipment's conductive surface, for safety and functional purposes. [1] The choice of earthing system can affect the safety and electromagnetic compatibility of the installation.

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    If the secondary is a delta winding, the ground may be connected to a center tap on one winding (high leg delta) or one phase may be grounded (corner grounded delta). A special purpose polyphase transformer is the zigzag transformer. There are many possible configurations that may involve more or fewer than six windings and various tap connections.

  8. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Any Δ-Y (delta-wye) connected transformer may be used for the purpose. A nine winding transformer (a "zig zag" transformer) may be used to balance the phase currents of a delta connected source with an unbalanced load. Low-resistance grounding systems use a neutral grounding resistor (NGR) to limit the fault current to 25 A or greater.

  9. Talk:Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Talk:Zigzag_transformer

    Most grounding transformers use zigzag windings but it is not the only configuration used. Also, zigzag windings are used as configurations in many topographies of transformers: wye/zigzag, delta/zigzag, zigzag/zigzag, zigzag/delta, zigzag/wye, delta//zigzag/zigzag (dual secondary). Some of the types are more common than others, of course.