When.com Web Search

  1. Ad

    related to: sprinklers not enough pressure to pump 2 gpm liquid co2 gas

Search results

  1. Results From The WOW.Com Content Network
  2. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Using metric units, the volumetric flow rate of a nozzle is given by =, [1] [2] where q is the flow rate in litres per minute ( l/min ), p is the pressure at the nozzle in bar and K is the K-factor is given in units of (/) /.

  3. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    Less water supply pressure is required with this looped main configuration as the hydraulic pressure drop is lower through the main as water can flow in two directions to any sprinkler. The branch lines may terminate in a dead end or may connect at each end to different (usually opposite) points on the looped main.

  4. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  5. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    A jockey pump is sized for a flow less than one sprinkler in order to ensure a system pressure drop significant enough to start the main fire pump. Jockey pumps are typically small multistage centrifugal pumps, and do not have to be listed or certified for fire system application. The control equipment for jockey pumps may however carry approvals.

  6. Liquid carbon dioxide - Wikipedia

    en.wikipedia.org/wiki/Liquid_carbon_dioxide

    Liquid carbon dioxide is the liquid state of carbon dioxide (CO 2 ), which cannot occur under atmospheric pressure. It can only exist at a pressure above 5.1 atm (5.2 bar; 75 psi), under 31.1 °C (88.0 °F) (temperature of critical point ) and above −56.6 °C (−69.9 °F) (temperature of triple point ). [ 1 ]

  7. Hydrocarbon dew point - Wikipedia

    en.wikipedia.org/wiki/Hydrocarbon_dew_point

    In the United States, the hydrocarbon dew point of processed, pipelined natural gas is related to and characterized by the term GPM which is the gallons of liquefiable hydrocarbons contained in 1,000 cubic feet (28 m 3) of natural gas at a stated temperature and pressure.

  8. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.

  9. Booster pump - Wikipedia

    en.wikipedia.org/wiki/Booster_pump

    Small compressed air powered breathing gas booster pump Haskell booster set up for charging rebreather cylinders from premix banks with low pressure compressor. A booster pump is a machine which increases the pressure of a fluid. It may be used with liquids or gases, and the construction details vary depending on the fluid.