When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Proportional counter - Wikipedia

    en.wikipedia.org/wiki/Proportional_counter

    The proportional counter is a type of gaseous ionization detector device used to measure particles of ionizing radiation.The key feature is its ability to measure the energy of incident radiation, by producing a detector output pulse that is proportional to the radiation energy absorbed by the detector due to an ionizing event; hence the detector's name.

  3. Glossary of chemistry terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_chemistry_terms

    Also acid ionization constant or acidity constant. A quantitative measure of the strength of an acid in solution expressed as an equilibrium constant for a chemical dissociation reaction in the context of acid-base reactions. It is often given as its base-10 cologarithm, p K a. acid–base extraction A chemical reaction in which chemical species are separated from other acids and bases. acid ...

  4. Glossary of biology - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_biology

    This glossary of biology terms is a list of definitions of fundamental terms and concepts used in biology, the study of life and of living organisms.It is intended as introductory material for novices; for more specific and technical definitions from sub-disciplines and related fields, see Glossary of cell biology, Glossary of genetics, Glossary of evolutionary biology, Glossary of ecology ...

  5. List of dimensionless quantities - Wikipedia

    en.wikipedia.org/wiki/List_of_dimensionless...

    chemistry (Proportion of "active" molecules or atoms) Arrhenius number = Svante Arrhenius: chemistry (ratio of activation energy to thermal energy) [1] Atomic weight: M: chemistry (mass of one atom divided by the atomic mass constant, 1 Da) Bodenstein number: Bo or Bd

  6. Counts per minute - Wikipedia

    en.wikipedia.org/wiki/Counts_per_minute

    Geiger-Müller counter with dual counts/dose rate display measuring a "point source". The dose per count is known for this specific instrument by calibration. The count rates of cps and cpm are generally accepted and convenient practical rate measurements. They are not SI units, but are de facto radiological units of measure in widespread use.

  7. Gaseous ionization detector - Wikipedia

    en.wikipedia.org/wiki/Gaseous_ionization_detector

    The term "gas proportional detector" (GPD) is generally used in radiometric practice, and the property of being able to detect particle energy is particularly useful when using large area flat arrays for alpha and beta particle detection and discrimination, such as in installed personnel monitoring equipment.

  8. Parts-per notation - Wikipedia

    en.wikipedia.org/wiki/Parts-per_notation

    Parts-per notations may be expressed in terms of any unit of the same measure. For instance, the expansion coefficient of some brass alloy, α = 18.7 ppm/°C, may be expressed as 18.7 (μm/m)/°C, or as 18.7 (μ in/in)/°C; the numeric value representing a relative proportion does not change with the adoption of a different unit of length.

  9. Rate-limiting step (biochemistry) - Wikipedia

    en.wikipedia.org/wiki/Rate-limiting_step...

    The terms are proportional to the limiting rate values of the enzymes. The first point to note from the above equation is that the pathway flux is a function of all the enzymes; there is no need for there to be a 'rate-limiting' step.