Reclamation, as it refers to refrigerants, is one of three components in a refrigerant management process. The EPA defines refrigerant reclamation as "Reclaim refrigerant means to reprocess refrigerant to at least the purity specified in appendix A to 40 CFR part 82, subpart F (based on AHRI Standard 700–1993, Specifications for Fluorocarbon ...
A refrigerant is a working fluid used in the cooling, heating, or reverse cooling/heating cycles of air conditioning systems and heat pumps, where they undergo a repeated phase transition from a liquid to a gas and back again.
A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...
Dichlorodifluoromethane (R-12 or CFC-12), the most commonly used Freon brand refrigerant prior to its ban in many countries in 1996 and total ban in 2010. 1,1,1,2-Tetrafluoroethane (R-134a or HFC-134a), one of the main replacements for the formerly widespread R-12. Opteon halogenated olefins now replacing Freons in many applications.
The cooling towers of a large chilled water system. As part of a chilled water system, the condenser water absorbs heat from the refrigerant in the condenser barrel of the water chiller and is then sent via return lines to a cooling tower, which is a heat exchange device used to transfer waste heat to the atmosphere.
A device that removes heat from a liquid via a vapor-compression or absorption refrigeration cycle. This cooled liquid flows through pipes in a building and passes through coils in air handlers, fan-coil units, or other systems, cooling and usually dehumidifying the air in the building. Chillers are of two types; air-cooled or water-cooled.
In many types of processes, combustion is used to generate heat, and the recuperator serves to recuperate, or reclaim this heat, in order to reuse or recycle it. The term recuperator refers as well to liquid-liquid counterflow heat exchangers used for heat recovery in the chemical and refinery industries and in closed processes such as ammonia-water or LiBr-water absorption refrigeration cycle.
Refrigerant recovery and recycling techniques and procedures; Leak checking; Sales restrictions and venting prohibitions - Listing of chemicals that fall under these requirements is part of the Significant New Alternatives Policy program; Record keeping requirements; Disposal and safety; Reclamation; Service practices. [4] [5]