When.com Web Search

  1. Ad

    related to: pressure transmitter calibration setup tool home depot

Search results

  1. Results From The WOW.Com Content Network
  2. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  3. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area. A pressure sensor usually acts as a transducer; it generates a signal as a function of the pressure imposed. Pressure sensors can vary drastically in technology, design, performance, application suitability and ...

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  5. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.

  6. Pneumatic tool - Wikipedia

    en.wikipedia.org/wiki/Pneumatic_tool

    Pneumatic tools are rated using several metrics: Free Speed (rpm), Air Pressure (psi/bar), Air Consumption (cfm/scfm or m3/min), Horse Power (hp), and spindle size. Each individual tool has its own specific requirements which determine their compatibility with air compressor systems.

  7. High-integrity pressure protection system - Wikipedia

    en.wikipedia.org/wiki/High-integrity_pressure...

    The scheme above presents three pressure transmitters (PT) connected to a logic solver. The solver will decide based on 2-out-of-3 voting whether or not to activate the final element. the 1oo2 solenoid panel decides which valve to be closed. The final elements consist here of two block valves that stop flow to the downstream facilities (right ...

  8. Precision measurement equipment laboratory - Wikipedia

    en.wikipedia.org/wiki/Precision_Measurement...

    The technicians who work in the PMEL will often specialize in one of these sections. The K-Sections are derived from the primary function of the TMDE. This is based upon the calibration authority. Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment.

  9. Highway Addressable Remote Transducer Protocol - Wikipedia

    en.wikipedia.org/wiki/Highway_Addressable_Remote...

    The HART Communication Protocol (Highway Addressable Remote Transducer) is a hybrid analog+digital industrial automation open protocol. Its most notable advantage is that it can communicate over legacy 4–20 mA analog instrumentation current loops, sharing the pair of wires used by the analog-only host systems.