When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).

  3. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).

  4. Closed-loop controller - Wikipedia

    en.wikipedia.org/wiki/Closed-loop_controller

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.

  5. Industrial process control - Wikipedia

    en.wikipedia.org/wiki/Industrial_process_control

    In complex processes the loops are interactive, so that the operation of one loop may affect the operation of another. The system diagram for representing control loops is a Piping and instrumentation diagram. Commonly used control systems include programmable logic controller (PLC), Distributed Control System (DCS) or SCADA.

  6. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    Tuning a control loop is the adjustment of its control parameters (proportional band/gain, integral gain/reset, derivative gain/rate) to the optimum values for the desired control response. Stability (no unbounded oscillation) is a basic requirement, but beyond that, different systems have different behavior, different applications have ...

  7. Control system - Wikipedia

    en.wikipedia.org/wiki/Control_system

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.

  8. Feedwater heater - Wikipedia

    en.wikipedia.org/wiki/Feedwater_heater

    A Rankine cycle with two steam turbines and a single open feedwater heater. A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating boiler. [1] [2] [3] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system ...

  9. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.