A single-leaf wall is a wall without a cavity or continuous vertical joint in its plane. A double-leaf wall is a wall consisting of two parallel leaves with the longitudinal joint between filled solidly with mortar and securely tied together with wall ties so as to result in common action under load.
The infill wall has the unique static function to bear its own weight. The infill wall is an external vertical opaque type of closure. With respect to other categories of wall, the infill wall differs from the partition that serves to separate two interior spaces, yet also non-load bearing, and from the load bearing wall.
This is the simplest arrangement of masonry units. If the wall is two wythes thick, one header is used to bind the two wythes together. [3] Header course: This is a course made up of a row of headers. [1] Bond course: This is a course of headers that bond the facing masonry to the backing masonry. [1] Plinth: The bottom course of a wall.
A cavity wall is composed of two masonry walls separated by an air space. The outer wall is made of brick and faces the outside of the building structure. [6] The inner wall may be constructed of masonry units such as concrete block, structural clay, brick or reinforced concrete. [6] These two walls are fastened together with metal ties or ...
A leaf is as thick as the width of one brick, but a wall is said to be one brick thick if it as wide as the length of a brick. Accordingly, a single-leaf wall is a half brick thickness; a wall with the simplest possible masonry transverse bond [definition needed] is said to be one brick thick, and so on. [21]
Core-and-veneer, brick and rubble, wall and rubble, ashlar and rubble, and emplekton all refer to a building technique where two parallel walls are constructed and the core between them is filled with rubble or other infill, creating one thick wall. [1] Originally, and in later poorly constructed walls, the rubble was not consolidated.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
EN 1996-1-2 deals with the design of masonry structures for the accidental situation of fire exposure, and is intended to be used in conjunction with EN 1996-1-1, EN 1996-2, 1996-3 and EN 1991-1-2. This part only identifies differences from, or supplements to, normal temperature design and it deals only with passive methods of fire protection.