External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...
In some systems, firefighters have the option of pumping a Fire Department Connection (FDC) which will increase the water pressure at a standpipe in the event of a fire pump failure or loss of pressure. Typically, these systems pressurize the sprinkler system or the standpipe but not both at the same time.
U.S. War Department adopted a standard Quartermaster's Department fire hose coupling, that proved troublesome and was abandoned even while the standard was still in effect. (1917 proceedings of the NFPA) 1904 2 + 1 ⁄ 2-inch ID, 3 + 1 ⁄ 16-inch OD, 7.5 tpi 3, 6 tpi 3 + 1 ⁄ 2-inch 7.5 tpi 4 + 1 ⁄ 2-inch, 4 tpi
A fire hydrant, fireplug, [1] firecock (archaic), [2] hydrant riser or Johnny Pump [3] [better source needed] is a connection point by which firefighters can tap into a water supply. It is a component of active fire protection. Underground fire hydrants have been used in Europe and Asia since at least the 18th century. Above-ground pillar-type ...
A short piece of fire hose, usually 10 to 20 feet (6.1 m) long, of large diameter, greater than 2.5 inches (64 mm) and as large as 6 inches (150 mm), used to move water from a fire hydrant to the fire engine, when the fire apparatus is parked close to the hydrant. Solid stream A fire-fighting water stream emitted from a smooth-bore nozzle.
A sprinkler activation will usually do less water damage than a fire department hose stream (which provide approximately 900 litres/min (250 US gallons/min). A typical sprinkler used for industrial manufacturing occupancies discharges about 75–150 litres/min (20–40 US gallons/min).
5-inch (13 cm) flex suction hose with Storz fittings, mounted on an engine. Flexible suction hose (Flex suction or suction hose), not to be confused with hard suction hose in U.S., is a specific type of fire hose used in drafting operations, when a fire engine uses a vacuum to draw water from a portable water tank, pool, or other static water source.
Standpipe may refer to: Standpipe (firefighting) , a rigid vertical or horizontal pipe to which fire hoses can be connected Standpipe (street) , an external freestanding pipe to provide running water in areas with no other water supply