When.com Web Search

  1. Ad

    related to: floating neutral generator wiring diagram pdf printable

Search results

  1. Results From The WOW.Com Content Network
  2. Floating ground - Wikipedia

    en.wikipedia.org/wiki/Floating_ground

    Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).

  3. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    [2] [4] Neutral grounding transformers are very common on generators in power plants and wind farms. [2] Neutral grounding transformers are sometimes applied on high-voltage (sub-transmission) systems, such as at 33 kV, where the circuit would otherwise not have a ground; for example, if a system is fed by a delta-connected transformer.

  4. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.

  5. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel. The ground loop between components C1 and C2 creates a second parallel path for the current. [8]

  6. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    Neutral is a circuit conductor that normally completes the circuit back to the source. NEC states that the neutral and ground wires should be connected at the neutral point of the transformer or generator, or otherwise some "system neutral point" but not anywhere else. [1]

  7. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    The second coils are then all tied together to form the neutral, and the phases are connected to the primary coils. Each phase, therefore, couples with each other phase, and the voltages cancel out. As such, there would be negligible current through the neutral point, as the Zig-Zag has a high positive and negative sequence impedance, with a ...

  8. AOL Mail

    mail.aol.com/?icid=aol.com-nav

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    The earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification , but also finds use for larger isolated loads such as water pumps.