  2. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram of the output voltages for a split-phase transformer.

  3. Single-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Single-phase_electric_power

    A single-phase polemount stepdown transformer in Canada. One supply phase (phase-to-neutral) from the utility is converted to split-phase for the customers. In electrical engineering, single-phase electric power (abbreviated 1φ ) is the distribution of alternating current electric power using a system in which all the voltages of the supply ...

  4. Voltage converter - Wikipedia

    en.wikipedia.org/wiki/Voltage_converter

    Most single phase alternating-current electrical outlets in the world supply power at 210–240 V or at 100–120 V. A transformer or autotransformer can be used; (auto)transformers are inherently reversible, so the same transformer can be used to step the voltage up, or step it down by the same ratio. Lighter and smaller devices can be made ...

  5. Mains electricity - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity

    In northern and central Europe, residential electrical supply is commonly 400 V three-phase electric power, which gives 230 V between any single phase and neutral; house wiring may be a mix of three-phase and single-phase circuits, but three-phase residential use is rare in the UK.

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    The voltages between the three phases are the same in magnitude, however the voltage magnitudes between a particular phase and the neutral vary. The phase-to-neutral voltage of two of the phases will be half of the phase-to-phase voltage. The remaining phase-to-neutral voltage will be √ 3 /2 the phase-to-phase voltage. So if A–B, B–C and ...

  7. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Transformers step down transmission voltages, 35 kV or more, down to primary distribution voltages. These are medium voltage circuits, usually 600–35 000 V. [1] From the transformer, power goes to the busbar that can split the distribution power off in multiple directions. The bus distributes power to distribution lines, which fan out to ...

  8. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common residential and small commercial service in Canada and the U.S., single split-phase, 240 V, features a neutral and two hot legs, 240 V to each other, and 120 V each to the neutral. The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral.

  9. Electric power conversion - Wikipedia

    en.wikipedia.org/wiki/Electric_power_conversion

    Consumer voltage converters (also known as "travel converters") are used when traveling between countries that use ~120 V versus ~240 V AC mains power. (There are also consumer "adapters" which merely form an electrical connection between two differently shaped AC power plugs and sockets , but these change neither voltage nor frequency.)