When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Safe operating area - Wikipedia

    en.wikipedia.org/wiki/Safe_operating_area

    Often, in addition to the continuous rating, separate SOA curves are also plotted for short duration pulse conditions (1 ms pulse, 10 ms pulse, etc.). The safe operating area curve is a graphical representation of the power handling capability of the device under various conditions.

  3. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.

  4. Latch-up - Wikipedia

    en.wikipedia.org/wiki/Latch-up

    In electronics, a latch-up is a type of short circuit which can occur in an integrated circuit (IC). More specifically, it is the inadvertent creation of a low-impedance path between the power supply rails of a MOSFET circuit, triggering a parasitic structure which disrupts proper functioning of the part, possibly even leading to its destruction due to overcurrent.

  5. Short circuit - Wikipedia

    en.wikipedia.org/wiki/Short_circuit

    A short circuit fault current can, within milliseconds, be thousands of times larger than the normal operating current of the system. [2] Damage from short circuits can be reduced or prevented by employing fuses , circuit breakers , or other overload protection , which disconnect the power in reaction to excessive current.

  6. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...

  7. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Fault tree analysis is one tool with which a protection engineer can compare the relative reliability of proposed protection schemes. Quantifying protection reliability is important for making the best decisions on improving a protection system, managing dependability versus security tradeoffs, and getting the best results for the least money.

  8. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  9. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    The I 2 t rating is related to the amount of energy let through by the fuse element when it clears the electrical fault. This term is normally used in short circuit conditions and the values are used to perform co-ordination studies in electrical networks. I 2 t parameters are provided by charts in manufacturer data sheets for each fuse family.

  1. Related searches bipolar short circuit fault protection society reviews yelp ratings free

    short circuit protectionshort circuit fault examples