A short circuit is an abnormal connection between two nodes of an electric circuit intended to be at different voltages. This results in an electric current limited only by the Thévenin equivalent resistance of the rest of the network which can cause circuit damage, overheating, fire or explosion.
The short circuit ratio (SCR) is an indicator of the strength of a network bus about the rated power of a device and is frequently used as a measure of system strength. A higher SCR value indicates a stronger system, meaning that the impact of disturbances on voltage and other variables will be minimized.
short-circuit test A test of machines or apparatus where the load terminals are directly connected; usually done at reduced power to prevent damage, but destructive short circuit testing may be carried out on circuit protective devices. short circuit A path in a circuit that has negligible resistance; often un-intended, a fault. shunt
An asymmetric or unbalanced fault does not affect each of the phases equally. Common types of asymmetric fault, and their causes: line-to-line fault - a short circuit between lines, caused by ionization of air, or when lines come into physical contact, for example due to a broken insulator. In transmission line faults, roughly 5% - 10% are ...
"A short circuit is a conductive path between two otherwise separate conductors, which links isolated networks or causes current to bypass its normal path. Often the short circuit is the result of an undesired event, and causes excessive current to lead to further unintended destructive consequences.
Power outages are categorized into three different phenomena, relating to the duration and effect of the outage: A transient fault is a loss of power typically caused by a fault on a power line, e.g. a short circuit or flashover. Power is automatically restored once the fault is cleared.
In a synchronous generator, [1] the short circuit ratio is the ratio of field current required to produce rated armature voltage at the open circuit to the field current required to produce the rated armature current at short circuit. [1] [2] This ratio can also be expressed as an inverse of the saturated [3] direct-axis synchronous reactance ...
Under short-circuit conditions, the calculated or measured maximum prospective short-circuit current may be many times the normal, rated current of the circuit. When electrical contacts open to interrupt a large current, there is a tendency for an arc to form between the opened contacts, which would allow the current to continue.