When.com Web Search

  1. Ads

    related to: 12-lead ecg interpretation

Search results

  1. Results From The WOW.Com Content Network
  2. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    A standard 12-lead ECG report (an electrocardiograph) shows a 2.5 second tracing of each of the twelve leads. The tracings are most commonly arranged in a grid of four columns and three rows. The first column is the limb leads (I, II, and III), the second column is the augmented limb leads (aVR, aVL, and aVF), and the last two columns are the ...

  3. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  4. Electrocardiography in myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography_in...

    In spite of these limitations, the 12 lead ECG stands at the center of risk stratification for the patient with suspected acute myocardial infarction. Mistakes in interpretation are relatively common, and the failure to identify high risk features has a negative effect on the quality of patient care. [3]

  5. Sinus rhythm - Wikipedia

    en.wikipedia.org/wiki/Sinus_rhythm

    In humans, for an ECG to be described as showing a sinus rhythm, the shape of the P wave in each of the 12 standard ECG leads should be consistent with a "typical P vector" of +50° to +80°. [2] This means that the P wave should be: always positive in lead I, lead II, and aVF; always negative in lead aVR

  6. Diagnosis of myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Diagnosis_of_myocardial...

    The standard 12 lead ECG does not directly examine the right ventricle, and is relatively poor at examining the posterior basal and lateral walls of the left ventricle. In particular, acute myocardial infarction in the distribution of the circumflex artery is likely to produce a nondiagnostic ECG. [ 10 ]

  7. Third-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/Third-degree_atrio...

    Since pacemaker correction of the third-degree block requires full-time pacing of the ventricles, a potential side effect is pacemaker syndrome, and may necessitate the use of a biventricular pacemaker, which has an additional 3rd lead placed in a vein in the left ventricle, providing more coordinated pacing of both ventricles.