Search results
Results From The WOW.Com Content Network
Standard K-Series Joists have a 2 + 1 ⁄ 2 inches (64 mm) end bearing depth so that, regardless of the overall joist depths, the tops of the joists lie in the same plane. Seat depths deeper than 2 + 1 ⁄ 2 inches (64 mm) can also be specified.
Wood furring strips typically measure 1 x 2 or 1 x 3 inches. They can be laid out perpendicular to studs or joists and nailed to them, or set vertically against an existing wall surface. The spacing between the strips depends on the type of finishing material. Wider spacing is typically used behind the heavy boards that support ceramic tiles.
The term binding joist is sometimes used to describe beams at floor level running perpendicular to the ridge of a gable roof and joined to the intermediate posts. Joists which land on a binding joist are called bridging joists. [4] [5] A large beam in the ceiling of a room carrying joists is a summer beam. A ceiling joist may be installed flush ...
The rim joist depth must match the I-joist size. Mismatches can strain the joist. A similar situation occurs where the I-joist crosses a main beam. Installing squash blocks (2×4 materials 1 ⁄ 16 in or 1.6 mm higher than the I-joist) alongside the I-joists transfers the load from the I-joist onto the beam. Missed nails and glue setting too ...
Trimmers are installed parallel to the primary floor or ceiling joists and support headers, which run perpendicular to the primary joists. [1] [2] It can also refer to a jack stud that supports a header above a window or door opening. Traditionally, a stud which was less than full length was sometimes referred to as a cripple. [3] [4] [5]
Joist bridging, or blocking, is used between floor or ceiling joists, but this is to prevent the joists from (twisting or rotating under load) rather than to prevent buckling in compression. Herringbone strutting may replace blocking with smaller, timber battens fixed diagonally, in pairs, between joists.
You can find instant answers on our AOL Mail help page. Should you need additional assistance we have experts available around the clock at 800-730-2563. Should you need additional assistance we have experts available around the clock at 800-730-2563.
In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...