When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-wire three-phase circuit is usually more economical than an equivalent two-wire single-phase circuit at the same line-to-ground voltage because it uses less conductor material to transmit a given amount of electrical power. [3] Three-phase power is mainly used directly to power large induction motors, other electric motors and other ...

  3. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  4. Maximum power transfer theorem - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_transfer_theorem

    It is a common misconception to apply the theorem in the opposite scenario. It does not say how to choose the source resistance for a given load resistance. In fact, the source resistance that maximizes power transfer from a voltage source is always zero (the hypothetical ideal voltage source), regardless of the value of the load resistance.

  5. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    Conductor sizes range from 12 mm 2 (#6 American wire gauge) to 750 mm 2 (1,590,000 circular mils area), with varying resistance and current-carrying capacity. For large conductors (more than a few centimetres in diameter), much of the current flow is concentrated near the surface due to the skin effect. The center of the conductor carries ...

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V.

  7. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. . Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing

  8. Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.

  9. Ohm's law - Wikipedia

    en.wikipedia.org/wiki/Ohm's_law

    As seen in the figure, the current does not increase linearly with applied voltage for a diode. One can determine a value of current (I) for a given value of applied voltage (V) from the curve, but not from Ohm's law, since the value of "resistance" is not constant as a function of applied voltage. Further, the current only increases ...