Search results
Results From The WOW.Com Content Network
The contact breaker is operated by an engine-driven cam.On an engine with a distributor, the contact breaker can be found beneath the distributor cap.The position of the contact breaker is set so that it opens (and hence generates a spark) at exactly the optimum moment to ignite the fuel/air mixture.
Spark plug with single side electrode An electric spark on the spark plug. A spark plug (sometimes, in British English, a sparking plug, [1] and, colloquially, a plug) is a device for delivering electric current from an ignition system to the combustion chamber of a spark-ignition engine to ignite the compressed fuel/air mixture by an electric spark, while containing combustion pressure within ...
When the contact breaker opens the circuit, the magnetic field collapses, causing a high electric voltage in the primary and secondary coils. However, due to the greater number of turns of the secondary coil, the voltage is much higher, causing a larger spark at the ignitor or spark plug, meaning more assured ignition.
An ignition magneto (also called a high-tension magneto) is an older type of ignition system used in spark-ignition engines (such as petrol engines). It uses a magneto and a transformer to make pulses of high voltage for the spark plugs. The older term "high-tension" means "high-voltage". [1]
Spark plug wires (also called high tension leads) are electrical cables used by older internal combustion engines to transmit high-voltage electricity from the distributor to the spark plugs. Tension in this instance is a synonym for voltage. High tension may also be referred to as HT. [1] Many modern engines use coil-on-plug ignition, a design ...
In spark-ignition internal combustion engines, knocking (also knock, detonation, spark knock, pinging or pinking) occurs when combustion of some of the air/fuel mixture in the cylinder does not result from propagation of the flame front ignited by the spark plug, but when one or more pockets of air/fuel mixture explode outside the envelope of the normal combustion front.
In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.
Simulation-based methods for time-based network analysis solve a circuit that is posed as an initial value problem (IVP). That is, the values of the components with memories (for example, the voltages on capacitors and currents through inductors) are given at an initial point of time t 0 , and the analysis is done for the time t 0 ≤ t ≤ t f ...