Search results
Results From The WOW.Com Content Network
In 1969, Hoffer concluded that a whole-body impedance measurement could predict total body water. The equation (the squared value of height divided by impedance measurements of the right half of the body) showed a correlation coefficient of 0.92 with total body water. This equation, Hoffer proved, is known as the impedance index used in BIA. [16]
Also called chordal or DC resistance This corresponds to the usual definition of resistance; the voltage divided by the current R s t a t i c = V I. {\displaystyle R_{\mathrm {static} }={V \over I}.} It is the slope of the line (chord) from the origin through the point on the curve. Static resistance determines the power dissipation in an electrical component. Points on the current–voltage ...
The lumped parameter model consists in a system of ordinary differential equations that adhere to the principles of conservation of mass and momentum balance. The model is obtained exploiting the electrical analogy where the current represents the blood flow, the voltage represents the pressure difference, the electric resistance plays the role of the vascular resistance (determined by the ...
Compliance is calculated using the following equation, where is the change in volume (mL), and is the change in pressure : [3] C = Δ V Δ P {\displaystyle C={\frac {\Delta V}{\Delta P}}} Physiologic compliance is generally in agreement with the above and adds d P d t {\textstyle {\tfrac {dP}{dt}}} as a common academic physiologic measurement ...
In both JS-001-2012 and MIL-STD-883H the charged human body is modeled by a 100 pF capacitor and a 1500 ohm discharging resistance. During testing, the capacitor is fully charged to several kilovolts (2 kV, 4 kV, 6 kV and 8 kV are typical standard levels) and then discharged through the resistor connected in series to the device under test.
Compared to other smaller vessels in the body, the artery has a much bigger diameter (4 mm), therefore the resistance is low. [ 25 ] The arm–leg (blood pressure) gradient is the difference between the blood pressure measured in the arms and that measured in the legs.
Electrodermal activity (EDA) is the property of the human body that causes continuous variation in the electrical characteristics of the skin. Historically, EDA has also been known as skin conductance , galvanic skin response (GSR), electrodermal response (EDR), psychogalvanic reflex (PGR), skin conductance response (SCR), sympathetic skin ...
Specific energy absorption rate (SAR) averaged over the whole body or over parts of the body, is defined as the rate at which energy is absorbed per unit mass of body tissue and is expressed in watts per kilogram (W/kg). Whole body SAR is a widely accepted measure for relating adverse thermal effects to RF exposure. [9]