For that, equivalent wye connections are used for generators, transformers, loads and motors. The stator windings of a practical delta-connected three-phase generator, shown in the following figure, can be converted to an equivalent wye-connected generator, using the six following formulas [a]: Practical generator connected in delta/triangle/pi.
A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...
A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.
ΔY- and YΔ-transformations are a tool both in pure graph theory as well as applications. Both operations preserve a number of natural topological properties of graphs. . For example, applying a YΔ-transformation to a 3-vertex of a planar graph, or a ΔY-transformation to a triangular face of a planar graph, results again in a planar graph.
A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units. An equivalent ...
A well known application of this method is the approximation of the transfer function of a pn junction diode. The transfer function of an ideal diode has been given at the top of this (non-linear) section. However, this formula is rarely used in network analysis, a piecewise approximation being used instead.
In three phase power circuits, three phase sources and loads can be connected in two different ways, called a "delta" connection and a "wye" connection. In analyzing circuits, sometimes it simplifies the analysis to convert between equivalent wye and delta circuits. This can be done with the wye-delta transform.
For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.