When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...

  3. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a "ground fault" or "earth fault", current flows into the earth.

  4. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    The fuse element, or "fuse link", is the replaceable portion of the assembly that melts and breaks the circuit when the electric current through it exceeds its rated current value. There are many types of fuse elements for many different uses such as a type T fuse also known as a "slow-blow fuse" being used for sidelines.

  5. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    Normal fast-blow fuses are the most general purpose fuses. A time-delay fuse (also known as an anti-surge or slow-blow fuse) is designed to allow a current which is above the rated value of the fuse to flow for a short period of time without the fuse blowing. These types of fuse are used on equipment such as motors, which can draw larger than ...

  6. Inrush current limiter - Wikipedia

    en.wikipedia.org/wiki/Inrush_current_limiter

    An inrush current limiter is a component used to limit inrush current to avoid gradual damage to components and avoid blowing fuses or tripping circuit breakers.Negative temperature coefficient (NTC) thermistors and fixed resistors are often used to limit inrush current.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. Crowbar (circuit) - Wikipedia

    en.wikipedia.org/wiki/Crowbar_(circuit)

    Once triggered, they depend on the current-limiting circuitry of the power supply or, if that fails, the blowing of the line fuse or tripping the circuit breaker. The name is derived from having the same effect as throwing a crowbar over exposed power supply terminals to short the output.

  9. Knob-and-tube wiring - Wikipedia

    en.wikipedia.org/wiki/Knob-and-tube_wiring

    Modern home buyers often find that existing K&T systems lack the capacity for today's levels of power use. First-generation wiring systems became susceptible to abuse by homeowners who would replace blown fuses with fuses rated for higher current. This overfusing of the circuits subjects wiring to higher levels of current and risks heat damage ...