However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm 2). The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor.
A single insulated conductor in free air has 70 A rating. Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. Electrical code rules will give ratings for wiring where short-term loads are present, for example, in a hoisting motor.
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
For wire sizes smaller than AWG No. 2 (33.6 mm 2, 0.0521 sq in), this term is also generally regarded as insignificant. R c , a {\textstyle R_{c,a}} is the effective thermal resistance between the conductor and the ambient conditions, which can require significant empirical or theoretical effort to estimate.
The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2 .
The following are nominal current ratings for copper conductors; long runs may require thicker wires to minimize voltage drop. White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits