A reinforced concrete column is a structural member designed to carry compressive loads, composed of concrete with an embedded steel frame to provide reinforcement. For design purposes, the columns are separated into two categories: short columns and slender columns.
In practical design, it is recommended to increase the factors as shown above. The following assumptions are made while deriving Euler's formula: [3] The material of the column is homogeneous and isotropic. The compressive load on the column is axial only. The column is free from initial stress. The weight of the column is neglected.
The slenderness ratio is an indicator of the specimen's resistance to bending and buckling, due to its length and cross section. If the slenderness ratio is less than the critical slenderness ratio, the column is considered to be a short column. In these cases, the Johnson parabola is more applicable than the Euler formula. [5]
Steel column members must be verified as adequate to prevent buckling after axial and moment requirements are met. There are currently two common methods of steel design: The first method is the Allowable Strength Design (ASD) method. The second is the Load and Resistance Factor Design (LRFD) method. Both use a strength, or ultimate level ...
EN 1994-1-2 deals with the design of composite steel and concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1994-1-1 and EN 1991-1-2. This part only identifies differences from, or supplements to, normal temperature design and deals only with passive methods of fire protection.
EN 1993-6 gives principles and application rules for the structural design of crane runaway beams and other crane supporting structures including columns and other member fabricated from steel. This part is intended to be used with Eurocode EN 1991 -1 and it covers overhead crane runaways inside buildings and outdoor overhead crane runaways.
The ACI 318 Building Code Requirements for Structural Concrete uses Limit State design. The ANSI/ AISC 360 Specification for Structural Steel Buildings , the ANSI/ AISI S-100 North American Specification for the Design of Cold Formed Steel Structural Members , and The Aluminum Association 's Aluminum Design Manual contain two methods of design ...
Structural design, therefore begins with specifying loads that act on the structure. The design loading for a structure is often specified in building codes. There are two types of codes: general building codes and design codes, engineers must satisfy all of the code's requirements in order for the structure to remain reliable.