Ad
related to: ici method of calculation for column design for steel building material
Search results
Results From The WOW.Com Content Network
A reinforced concrete column is a structural member designed to carry compressive loads, composed of concrete with an embedded steel frame to provide reinforcement. For design purposes, the columns are separated into two categories: short columns and slender columns.
Fig. 2: Column effective length factors for Euler's critical load. In practical design, it is recommended to increase the factors as shown above. The following assumptions are made while deriving Euler's formula: [3] The material of the column is homogeneous and isotropic. The compressive load on the column is axial only.
Steel column members must be verified as adequate to prevent buckling after axial and moment requirements are met. There are currently two common methods of steel design: The first method is the Allowable Strength Design (ASD) method. The second is the Load and Resistance Factor Design (LRFD) method. Both use a strength, or ultimate level ...
The slenderness ratio is an indicator of the specimen's resistance to bending and buckling, due to its length and cross section. If the slenderness ratio is less than the critical slenderness ratio, the column is considered to be a short column. In these cases, the Johnson parabola is more applicable than the Euler formula. [5]
Allowable Stress Design philosophy was left unsupported by AISC after the 9th edition of the manual which remained an acceptable reference design standard in evolving building codes (e.g. International Building Code by the International Code Council). This presented problems since new research, engineering concepts and design philosophy were ...
EN 1994-1-2 deals with the design of composite steel and concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1994-1-1 and EN 1991-1-2. This part only identifies differences from, or supplements to, normal temperature design and deals only with passive methods of fire protection.
A clear distinction is made between the ultimate state (US) and the ultimate limit state (ULS). The Ultimate State is a physical situation that involves either excessive deformations sufficient to cause collapse of the component under consideration or the structure as a whole, or deformations exceeding values considered to be the acceptable tolerance.
EN 1993-1-2 deals with the design of steel structures for the accidental situation of fire exposure and it has to be used in conjunction with EN 1993-1-1 and EN 1991-1-2. This part only identifies differences from, or supplements to, normal temperature design. EN 1993-1-2 deals only with passive methods of fire protection.