When.com Web Search

  1. Ads

    related to: 4 awg aluminum building wire

Search results

  1. Results From The WOW.Com Content Network
  2. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Sizes with multiple zeros are successively thicker than 0 AWG and can be denoted using "number of zeros/0", for example 4/0 AWG for 0000 AWG. For an m /0 AWG wire, use n = −(m − 1) = 1 − m in the above formulas. For instance, for 0000 AWG or 4/0 AWG, use n = −3.

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    For instance, instead of 14 AWG (American wire gauge) copper wire, aluminium wiring would need to be 12 AWG on a typical 15 ampere lighting circuit, though local building codes vary. Solid aluminium conductors were originally made in the 1960s from a utility-grade aluminium alloy that had undesirable properties for a building wire, and were ...

  5. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    IEC 60228, the metric wire-size standard used in most parts of the world. Circular mil, Electrical industry standard for wires larger than 4/0. American Wire Gauge (AWG), used primarily in the US and Canada; Standard Wire Gauge (SWG), the British imperial standard BS3737; Jewelry wire gauge; Body jewelry sizes

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  7. Talk:Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Talk:Aluminum_building_wiring

    No, that's not the case. Aluminum conductors are required to be larger for the same current rating. Equivalently, the same size aluminum wire carries less current than a copper wire. Here's what Rule 240.4(D) says for maximum overcurrent size: 14 AWG - 15 amps copper, no rating for aluminum; 12 AWG - 20 A Cu, 15 A for Al; 10 AWG - 30 A Cu, 25 A ...