A variation in standard temperature can result in a significant volumetric variation for the same mass flow rate. For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C).
For some usage examples, consider the conversion of 1 SCCM to kg/s of a gas of molecular weight , where is in kg/kmol. Furthermore, consider standard conditions of 101325 Pa and 273.15 K, and assume the gas is an ideal gas (i.e., =).
With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...
Standard cubic feet per minute (SCFM) is a volumetric flow-rate corrected to a set of "standardized" conditions of pressure, temperature, and relative humidity. The standard conditions are often defined as 14.7 psia, temperature 70°F and relative humidity 0%, but the conditions may vary depending on the "standard" used.
Once two of the three reduced properties are found, the compressibility chart can be used. In a compressibility chart, reduced pressure is on the x-axis and Z is on the y-axis. When given the reduced pressure and temperature, find the given pressure on the x-axis. From there, move up on the chart until the given reduced temperature is found.
Pollution regulations in the United States typically reference their pollutant limits to an ambient temperature of 20 to 25 °C as noted above. In most other nations, the reference ambient temperature for pollutant limits may be 0 °C or other values. 1 percent by volume = 10,000 ppmv (i.e., parts per million by volume).
The reduced temperature of a fluid is its actual temperature, divided by its critical temperature: [1] = where the actual temperature and critical temperature are expressed in absolute temperature scales (either Kelvin or Rankine). Both the reduced temperature and the reduced pressure are often used in thermodynamical formulas like the Peng ...
21 MPa 3,000 psi Ballistic pressure exerted as high-power bullet strikes a solid bulletproof object [citation needed] 22 MPa 3,200 psi Critical pressure of water 28 MPa 4,100 psi Overpressure caused by the bomb explosion during the Oklahoma City bombing [72] 40 MPa 5,800 psi Water pressure at the depth of the wreck of the Titanic: 69 MPa 10,000 psi