The SI unit of power for heating and cooling systems is the watt. Btu per hour (Btu/h) is sometimes used in North America and the United Kingdom - the latter for air conditioning mainly, though "Btu/h" is sometimes abbreviated to just "Btu". [18] MBH—thousands of Btu per hour—is also common. [19] 1 W is approximately 3.412142 Btu/h [20]
HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1][2] It therefore has units of BTU/watt-hr. The higher the HSPF rating of a unit, the more energy efficient it is.
The equations for the use of the data retrieved from these tables are very simple. Q= heat gain, usually heat gain per unit time. A= surface area. U= Overall heat transfer coefficient. CLTD= cooling load temperature difference. SCL= solar cooling load factor. CLF= cooling load factor. SC= shading coefficient.
Therm. The therm (symbol, thm) is a non- SI unit of heat energy equal to 100,000 British thermal units (BTU), [1] and approximately 105 megajoules, 29.3 kilowatt-hours, 25,200 kilocalories and 25.2 thermies. One therm is the energy content of approximately 100 cubic feet (2.83 cubic metres) of natural gas at standard temperature and pressure.
The SI unit is watt (W). Another unit common in non-metric regions or sectors is the ton of refrigeration, which describes the amount of water at freezing temperature that can be frozen in 24 hours, equivalent to 3.5 kW or 12,000 BTU/h. [1] [2] [3] The basic SI units equation for deriving cooling capacity is of the form:
The R-value (in K ⋅ m 2/ W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]. R-value is the temperature difference per unit of heat flux needed to sustain one unit of heat flux between the ...
The NRC HSPFs ranged from 8.7 to 12.8 BTU/hr/watt (2.6 to 3.8 in nondimensional factors, or 255% to 375% seasonal average electricity utilization efficiency) for the most populated regions of Canada.
It quantifies how effectively a material can resist the transfer of heat through conduction, convection, and radiation. It has the units square metre kelvins per watt (m 2 ⋅K/W) in SI units or square foot degree Fahrenheit–hours per British thermal unit (ft 2 ⋅°F⋅h/Btu) in imperial units. The higher the thermal insulance, the better a ...