When.com Web Search

  1. Ads

    related to: determining trach suction catheter size

Search results

  1. Results From The WOW.Com Content Network
  2. French catheter scale - Wikipedia

    en.wikipedia.org/wiki/French_catheter_scale

    The French scale measures the outer diameter of the catheter, not the size of the internal drainage channel (inner diameter). For instance, a two-way catheter of 20 Fr and a three-way catheter of 20 Fr have the same outer diameter, but the three-way catheter has an additional channel for irrigation, reducing the size of its drainage channel.

  3. Laryngeal tube - Wikipedia

    en.wikipedia.org/wiki/Laryngeal_tube

    The re-usable models can be autoclaved up to 50 times, while the modified laryngeal tube (Suction) incorporates an extra lumen for inserting a gastric tube or suction system. There are six sizes of the laryngeal tube, ranging from newborn (size 0) to large adult (size 5). The connector of the tube is color-coded for each size.

  4. Tracheal tube - Wikipedia

    en.wikipedia.org/wiki/Tracheal_tube

    An endotracheal tube is a specific type of tracheal tube that is nearly always inserted through the mouth (orotracheal) or nose (nasotracheal). A tracheostomy tube is another type of tracheal tube; this 50–75-millimetre-long (2.0–3.0 in) curved metal or plastic tube may be inserted into a tracheostomy stoma (following a tracheotomy ) to ...

  5. Instruments used in anesthesiology - Wikipedia

    en.wikipedia.org/wiki/Instruments_used_in...

    Yankauer suction tip: Suction catheters used to remove secretions from the mouth, oropharynx, trachea and bronchi: Peripheral venous catheter: Water & sand weight bag: Artificial resuscitator (Bag valve mask) manual ventilation Bain circuit: respiratory maintenance circuit Laryngoscope: used to view larynx including the vocal cords, the glottis ...

  6. Suction Assisted Laryngoscopy Airway Decontamination

    en.wikipedia.org/wiki/Suction_Assisted...

    Hold the suction catheter (wide-bore, rigid) in a clenched-fisted right hand, with the distal end of the catheter pointing caudad and posterior, to enable manipulation of the tongue and mandible as required. The curve of the rigid suction catheter should mirror the curve of the structures of the upper airway: 3.

  7. Tracheal intubation - Wikipedia

    en.wikipedia.org/wiki/Tracheal_intubation

    The tracheal tube exchanger is a hollow catheter, 56 to 81 cm (22.0 to 31.9 in) in length, that can be used for removal and replacement of tracheal tubes without the need for laryngoscopy. [22] The Cook Airway Exchange Catheter (CAEC) is another example of this type of catheter; this device has a central lumen (hollow channel) through which ...