When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    A high-voltage current transformer may contain several cores, each with a secondary winding, for different purposes (such as metering circuits, control, or protection). [7] A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.

  3. Voltage transformer - Wikipedia

    en.wikipedia.org/wiki/Voltage_transformer

    A capacitor voltage transformer (CVT), is a transformer used in power systems to step down extra high voltage signals and provide a low voltage signal to the actual VT (voltage transformer) used for operating metering/protective relays due to a lower cost than an electromagnetic PT. The circuit diagram for a simple capacitor voltage transformer

  4. Instrument transformer - Wikipedia

    en.wikipedia.org/wiki/Instrument_transformer

    This is a common method used in portable current measuring instruments but permanent installations use more economical types of the current transformer. Specially constructed wideband CTs are also used, usually with an oscilloscope , to measure high frequency waveforms or pulsed currents within pulsed power systems.

  5. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    Circuit diagram for open-circuit test. The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of ...

  6. Rogowski coil - Wikipedia

    en.wikipedia.org/wiki/Rogowski_coil

    Traditional split-core current transformers do not require integrator circuits. The integrator is lossy, so the Rogowski coil does not have a response down to DC; neither does a conventional current transformer (see Néel effect coils for DC). However, they can measure very slow changing currents with frequency components down to 1 Hz and less.

  7. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    RCDs exist in multiple sub-types, but the most basic form simply consists of a current transformer, in which the line and neutral conductors for the circuit are wound around a toroidal transformer core, and should there be a current leak between line and earth (ground), bypassing neutral, the imbalance in current flow between the line and ...

  8. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    Diagram of center-tapped transformer. In electronics, a center tap (CT) is a contact made to a point halfway along a winding of a transformer or inductor, or along the element of a resistor or a potentiometer. Taps are sometimes used on inductors for the coupling of signals, and may not necessarily be at the half-way point, but rather, closer ...

  9. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A short-circuit test for determination of transformer impedance and losses is carried out with relatively low power applied to the transformer, and with winding currents of the same magnitude as in operation.