When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    The tonometer tip rests on the cornea with a constant appositional force of one gram. When the sensor is subjected to a change in pressure, the electrical resistance is altered and the tonometer's computer calculates a change in pressure according to the change in resistance. A complete measurement cycle requires about eight seconds of contact ...

  3. Schiøtz tonometer - Wikipedia

    en.wikipedia.org/wiki/Schiøtz_tonometer

    The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.

  4. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    A patient in front of a tonometer. Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1]

  5. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Theoretically, average corneal rigidity (taken as 520 μm for GAT) and the capillary attraction of the tear meniscus cancel each other out when the flattened area has the 3.06 mm diameter contact surface of the Goldmann prism, which is applied to the cornea using the Goldmann tonometer with a measurable amount of force from which the IOP is ...

  6. Imbert-Fick law - Wikipedia

    en.wikipedia.org/wiki/Imbert-Fick_law

    Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.

  7. Corneal topography - Wikipedia

    en.wikipedia.org/wiki/Corneal_topography

    Corneal topography instruments generate a measurement called simulated keratometry (SimK), which approximates the classic measurement of the widely used keratometer. Another novel use of corneal topographic data is called CorT, which has been shown to quantify refractive astigmatism more accurately than SimK and other approaches. [ 8 ]

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Gonioscopy - Wikipedia

    en.wikipedia.org/wiki/Gonioscopy

    Gonioscopy indicates the angular width of the iridocorneal angle by the number of ocular structures visible above the rim of the iris. Generally the more structures visible, the wider the angle. However, not all structures may be easily discriminated, especially the faint Schwalbe's line at the top of the stack.