When.com Web Search

  1. Ads

    related to: function of breather in transformer switch for dryer vent pipe

Search results

  1. Results From The WOW.Com Content Network
  2. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    In the U.S., every plumbing fixture must also be coupled to the system's vent piping. [1] Without a vent, negative pressure can slow the flow of water leaving the system, resulting in clogs, or cause siphonage to empty a trap. The high point of the vent system (the top of its "soil stack") must be open to the exterior at atmospheric pressure.

  3. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    As these need to operate in any orientation, they use a different mechanism rather than a float. The hygroscopic vent system uses hygroscopic cellulose fibre discs. [7] These are small discs of material that expand when wet and shrink if warm and dry. A dry valve acts as an air vent until a dribble of water passes through it and swells the ...

  4. Breather switch - Wikipedia

    en.wikipedia.org/wiki/Breather_switch

    A breather switch, expansion joint, or adjustment switch is an intentional gap in railway tracks to allow for thermal expansion in long sections of otherwise unbroken rail. . They are placed between very long sections of continuous welded rail or at the transition from continuous welded rail to jointed track, and commonly in the vicinity of bridges, viaducts and tunnels where the ...

  5. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  6. Breather - Wikipedia

    en.wikipedia.org/wiki/Breather

    A discrete breather is a breather solution on a nonlinear lattice. The term breather originates from the characteristic that most breathers are localized in space and oscillate in time. [1] But also the opposite situation: oscillations in space and localized in time [clarification needed], is denoted as a breather.

  7. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer A zone damper (also known as a Volume Control Damper or VCD ) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system.

  8. Disconnector - Wikipedia

    en.wikipedia.org/wiki/Disconnector

    A switch disconnector combines the properties of a disconnector and a load switch, [1] so it provides the safety isolation function while being able to make and break nominal currents. Integrated disconnecting switch

  9. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...