When.com Web Search

  1. Ad

    related to: gas volume conversion calculator liters

Search results

  1. Results From The WOW.Com Content Network
  2. Standard litre per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_litre_per_minute

    In the SI system of units, the preferred unit for volumetric flow rate is cubic meter per second, equivalent to 60,000 liters per minute. If the gas is to be considered as an ideal gas, then SLPM can be expressed as mole per second using the molar gas constant = 8.314510 J⋅K −1 ⋅mol −1: = = mol/s.

  3. Molar volume - Wikipedia

    en.wikipedia.org/wiki/Molar_volume

    The ideal gas equation can be rearranged to give an expression for the molar volume of an ideal gas: = = Hence, for a given temperature and pressure, the molar volume is the same for all ideal gases and is based on the gas constant: R = 8.314 462 618 153 24 m 3 ⋅Pa⋅K −1 ⋅mol −1, or about 8.205 736 608 095 96 × 10 −5 m 3 ⋅atm⋅K ...

  4. Volume units used in petroleum engineering - Wikipedia

    en.wikipedia.org/wiki/Volume_units_used_in...

    Oil conversion factor from m³ to bbl (or stb) is 6.28981100 Gas conversion factor from standard m³ to scf is 35.314666721 Note that the m³ gas conversion factor takes into account a difference in the standard temperature base for measurement of gas volumes in metric and imperial units.

  5. Standard temperature and pressure - Wikipedia

    en.wikipedia.org/wiki/Standard_temperature_and...

    The molar volume of gases around STP and at atmospheric pressure can be calculated with an accuracy that is usually sufficient by using the ideal gas law. The molar volume of any ideal gas may be calculated at various standard reference conditions as shown below: V m = 8.3145 × 273.15 / 101.325 = 22.414 dm 3 /mol at 0 °C and 101.325 kPa

  6. Gasoline gallon equivalent - Wikipedia

    en.wikipedia.org/wiki/Gasoline_gallon_equivalent

    One GGE of CNG pressurized at 2,400 psi (17 MPa) is 0.77 cubic feet (22 litres; 5.8 US gallons). This volume of CNG at 2,400 psi has the same energy content as one US gallon of gasoline (based on lower heating values: 148,144 BTU/cu ft (1,533.25 kWh/m 3) of CNG and 114,000 BTU/US gal (8.8 kWh/L) of gasoline. [22]

  7. Ideal gas law - Wikipedia

    en.wikipedia.org/wiki/Ideal_gas_law

    Isotherms of an ideal gas for different temperatures. The curved lines are rectangular hyperbolae of the form y = a/x. They represent the relationship between pressure (on the vertical axis) and volume (on the horizontal axis) for an ideal gas at different temperatures: lines that are farther away from the origin (that is, lines that are nearer to the top right-hand corner of the diagram ...

  8. Standard cubic foot - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_foot

    Yet other definitions are in use for industrial gas, [5] where, in the US, a standard cubic foot for industrial gas use is defined at 70 °F (21.1 °C) and 14.696 psia (101.325 kPa), while in Canada, a standard cubic meter for industrial gas use is defined at 15 °C (59 °F) and 101.325 kPa (14.696 psia).

  9. Volume (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Volume_(thermodynamics)

    The partial volume of a particular gas is a fraction of the total volume occupied by the gas mixture, with unchanged pressure and temperature. In gas mixtures, e.g. air, the partial volume allows focusing on one particular gas component, e.g. oxygen.