Search results
Results From The WOW.Com Content Network
It is measured by dividing the pulsatility index of the middle cerebral artery of the foetus by the pulsatility index of the umbilical artery of the foetus. A cerebroplacental ratio lower than 1-1.1 in uncomplicated pregnancies is indicative of placental insufficiency, independent of the actual fetal size.
It is used in ultrasound testing of umbilical artery for placental insufficiency. RI should not exceed 0.60 at 30 weeks of gestation. [5] It is also used to assess the kidneys for medical renal disease, as can occur with diabetes or kidney transplants damaged by rejection. [6]
The umbilical arteries are actually the anterior division of the internal iliac arteries, and retain part of this function after birth. [3] The umbilical arteries are one of two arteries in the human body, that carry deoxygenated blood, the other being the pulmonary arteries. The pressure inside the umbilical artery is approximately 50 mmHg. [4]
Artist's depiction of a foetus at 38 weeks' gestation. Foetal cerebral redistribution or 'brain-sparing' is a diagnosis in foetal medicine.It is characterised by preferential flow of blood towards the brain at the expense of the other vital organs, and it occurs as a haemodynamic adaptation in foetuses which have placental insufficiency.
The optimal timing of delivery for a fetus with IUGR is unknown. However, the timing of delivery is currently based on the cause of IUGR [6] and parameters collected from the umbilical artery doppler. Some of these include: pulsatility index, resistance index, and end-diastolic velocities, which are measurements of the fetal circulation. [26]
One parameter to quantify this difference is the pulsatility index (PI), which is equal to the difference between the peak systolic velocity and the minimum diastolic velocity divided by the mean velocity during the cardiac cycle. This value decreases with distance from the heart.
Histopathology of placenta with increased syncytial knotting of chorionic villi, with two knots pointed out. The following characteristics of placentas have been said to be associated with placental insufficiency, however all of them occur in normal healthy placentas and full term healthy births, so none of them can be used to accurately diagnose placental insufficiency: [citation needed]
Twin anemia-polycythemia sequence (TAPS) is a chronic type of unbalanced fetal transfusion in monochorionic twins that results in polycythemia in the TAPS recipient and anemia in the TAPS donor due to tiny placental anastomoses. [1]