The SEER rating of a unit is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is the ratio of cooling in British thermal units (BTUs) to the energy consumed in watt-hours.
In the United Kingdom, a Seasonal Energy Efficiency ratio (SEER) for refrigeration and air conditioning products, similar to the ESEER but with different load profile weighting factors, is used for part of the Building Regulations Part L calculations within the Simplified Building Energy Model (SBEM) software, and are used in the production of Energy Performance Certificates (EPC) for new ...
seer = BTU/watt-hr. The SEER Rating. Also, although the SEER is commonly defined as a ratio, and would therefore change or vary with operational conditions of the system, the SEER is also (and perhaps upmost) a rating determined by the manufacturer of the system, and therefore has the contrasting property of being a fixed quantity.
The higher the HSPF rating of a unit, the more energy efficient it is. An electrical resistance heater, which is not considered efficient, has an HSPF of 3.41. [3] Depending on the system, an HSPF ≥ 9 can be considered high efficiency and worthy of a US Energy Tax Credit. [4]
The energy factor metric only applies to residential water heaters, which are currently defined by fuel, type, and input capacity. [5] Generally, the EF number represents the thermal efficiency of the water heater as a percentage, since it is an average of the ratio of the theoretical heat required to raise the temperature of water drawn to the amount of energy actually consumed by the water ...
The COP of absorption chillers can be improved by adding a second or third stage. Double and triple effect chillers are significantly more efficient than single effect chillers, and can surpass a COP of 1. They require higher pressure and higher temperature steam, but this is still a relatively small 10 pounds of steam per hour per ton of cooling.
The annual fuel utilization efficiency (AFUE; pronounced 'A'-'Few' or 'A'-'F'-'U'-'E') is a thermal efficiency measure of space-heating furnaces and boilers.The AFUE differs from the true 'thermal efficiency' in that it is not a steady-state, peak measure of conversion efficiency, but instead attempts to represent the actual, season-long, average efficiency of that piece of equipment ...
In boilers, economizers are heat exchange devices that heat fluids, usually water, up to but not normally beyond the boiling point of that fluid. Economizers are so named because they can make use of the enthalpy in fluid streams that are hot, but not hot enough to be used in a boiler, thereby recovering more useful enthalpy and improving the boiler's efficiency.