A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.
[3] [4] The most common approach for accounting for matrix effects is to build a calibration curve using standard samples with known analyte concentration and which try to approximate the matrix of the sample as much as possible. [2] This is especially important for solid samples where there is a strong matrix influence. [5]
There is also a separate marine calibration curve, as radiocarbon concentrations differ between the ocean and atmosphere. [13] The calibration curve for the southern hemisphere is known as the SHCal as opposed to the IntCal for the northern hemisphere; the most recent version was published in 2020.
Standard solutions are commonly used to determine the concentration of an analyte species via calibration curve. A calibration curve is obtained by measuring a series of standard solutions with known concentrations, which can be used to determine the concentration of an unknown sample using linear regression analysis. [10]
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
The "Food Wish Method": Chef John's Mathematical Formula for Cooking Prime Rib. Multiply the exact weight of your prime rib by 5 minutes (round up to the nearest minute).
For example, if the GPC calibration curve is known for polystyrene in toluene, polyethylene in toluene can be run in a GPC and the molecular weight of polyethylene can be found according to the polystyrene calibration curve via the above equation. [3]