Search results
Results From The WOW.Com Content Network
Feeder busway is used to interconnect equipment, such as between a transformer and a switchgear line up. A variant type is a low-impedance busway, which is designed to have lower voltage drop by virtue of close spacing of bus bars, which reduces inductive reactance. A trolley busway provides power to equipment that must be frequently moved.
The low impedance and positioning of the electrode allows the activity of a large number of neurons to contribute to the signal. The unfiltered signal reflects the sum of action potentials from cells within approximately 50-350 μm from the tip of the electrode [2] [3] and slower ionic events from within 0.5–3 mm from the tip of the electrode ...
In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant.
Constant binary 1 and 0 levels are shown, as well as transitions from 0 to 1, 1 to 0, 0 to 1 to 0, and 1 to 0 to 1. In telecommunications , an eye pattern , also known as an eye diagram , is an oscilloscope display in which a digital signal from a receiver is repetitively sampled and applied to the vertical input ( y-axis ), while the data rate ...
Passive diffusion across a cell membrane.. Passive transport is a type of membrane transport that does not require energy to move substances across cell membranes. [1] [2] Instead of using cellular energy, like active transport, [3] passive transport relies on the second law of thermodynamics to drive the movement of substances across cell membranes.
Developmental bioelectricity is a sub-discipline of biology, related to, but distinct from, neurophysiology and bioelectromagnetics.Developmental bioelectricity refers to the endogenous ion fluxes, transmembrane and transepithelial voltage gradients, and electric currents and fields produced and sustained in living cells and tissues.
APB is designed for low bandwidth control accesses, for example register interfaces on system peripherals. This bus has an address and data phase similar to AHB, but a much reduced, low complexity signal list (for example no bursts). Furthermore, it is an interface designed for a low frequency system with a low bit width (32 bits).
A fault current limiter is a nonlinear element which has a low impedance at normal current levels, but presents a higher impedance at fault current levels. Further, this change is extremely rapid, before a circuit breaker can trip a few milliseconds later.