  1. Results From The WOW.Com Content Network
  2. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    An induction generator produces electrical power when its rotor is turned faster than the synchronous speed. For a four-pole motor (two pairs of poles on stator) powered by a 60 Hz source, the synchronous speed is 1800 rotations per minute (rpm) and 1500 RPM powered at 50 Hz. The motor always turns slightly slower than the synchronous speed.

  3. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    The rating of a brushless motor is the ratio of the motor's unloaded rotational speed (measured in RPM) to the peak (not RMS) voltage on the wires connected to the coils (the back EMF). For example, an unloaded motor of K v {\displaystyle K_{\text{v}}} = 5,700 rpm/V supplied with 11.1 V will run at a nominal speed of 63,270 rpm (= 5,700 rpm/V ...

  4. Critical speed - Wikipedia

    en.wikipedia.org/wiki/Critical_speed

    Many practical applications suggest as good practice that the maximum operating speed should not exceed 75% of the critical speed [citation needed]; however, some systems operate above the first critical speed, or supercritically. In such cases, it is important to accelerate the shaft through the first natural frequency quickly so that large ...

  5. Constant speed drive - Wikipedia

    en.wikipedia.org/wiki/Constant_Speed_Drive

    Constant speed drive for Boeing 727, made by Sundstrand Corporation. A constant speed drive (CSD) also known as a constant speed generator, is a type of transmission that takes an input shaft rotating at a wide range of speeds, delivering this power to an output shaft that rotates at a constant speed, despite the varying input.

  6. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    An engine–generator is the combination of an electrical generator and an engine (prime mover) mounted together to form a single piece of equipment. This combination is also called an engine–generator set or a gen-set. In many contexts, the engine is taken for granted and the combined unit is simply called a generator. An engine–generator ...

  7. Motor drive - Wikipedia

    en.wikipedia.org/wiki/Motor_drive

    An adjustable speed motor drive is a system that includes a motor that has multiple operating speeds. A variable speed motor drive is a system that includes a motor that is continuously variable in speed. If the motor is generating electrical energy rather than using it, the motor drive could be called a generator drive but is often still ...

  8. Power band - Wikipedia

    en.wikipedia.org/wiki/Power_band

    While engines and motors have a large range of operating speeds, the power band is usually a much smaller range of engine speed, only half or less of the total engine speed range [1] (electric motors are an exception—see the section on electric motors below). Specifically, power band is the range of RPM around peak power output.

  9. Turbo generator - Wikipedia

    en.wikipedia.org/wiki/Turbo_generator

    The rotor of a turbo generator is a non-salient pole type usually with two poles. [5] The normal speed of a turbo generator is 1500 or 3000 rpm with four or two poles at 50 Hz (1800 or 3600 rpm with four or two poles at 60 Hz). The rotating parts of a turbo generator are subjected to high mechanical stresses because of the high operation speed.