When.com Web Search

  1. Ad

    related to: conduit tracking methods chart for wire size

Search results

  1. Results From The WOW.Com Content Network
  2. Knob-and-tube wiring - Wikipedia

    en.wikipedia.org/wiki/Knob-and-tube_wiring

    Earthing systems. v. t. e. Knob-and-tube wiring (sometimes abbreviated K&T) is an early standardized method of electrical wiring in buildings, in common use in North America from about 1880 to the 1930s. [1][2] It consisted of single-insulated copper conductors run within wall or ceiling cavities, passing through joist and stud drill-holes via ...

  3. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Galvanized rigid conduit (GRC) is galvanized steel tubing, with a tubing wall that is thick enough to allow it to be threaded. Its common applications are in commercial and industrial construction. [1] It is designed to protect wire and connectors. Intermediate metal conduit (IMC) is a steel tubing heavier than EMT but lighter than RMC. It may ...

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  5. Comparative Tracking Index - Wikipedia

    en.wikipedia.org/wiki/Comparative_Tracking_Index

    To measure the tracking, 50 drops of 0.1% ammonium chloride solution are dropped on the material, and the voltage measured for a 3 mm thickness is considered representative of the material performance. Also term PTI (Proof Tracking Index) is used: it means voltage at which during testing on five samples the samples pass the test with no failures.

  6. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Electrical wiring is an electrical installation of cabling and associated devices such as switches, distribution boards, sockets, and light fittings in a structure. Wiring is subject to safety standards for design and installation. Allowable wire and cable types and sizes are specified according to the circuit operating voltage and electric ...

  7. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    American wire gauge. American Wire Gauge (AWG) is a logarithmic stepped standardized wire gauge system used since 1857, predominantly in North America, for the diameters of round, solid, nonferrous, electrically conducting wire. Dimensions of the wires are given in ASTM standard B 258. [1] The cross-sectional area of each gauge is an important ...

  8. Conduit current collection - Wikipedia

    en.wikipedia.org/wiki/Conduit_current_collection

    Conduit for current collection between the rails of streetcars in Washington, D.C., 1939. Washington installed the system in 1895 [1] and it remained in operation until 1962 [2] Conduit current collection is an obsolete system that was used by some electric tramways to pass current to streetcars via a "conduit", a small tunnel under the roadway.

  9. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60642 Piezoelectric ceramic resonator units. IEC 60644 Specification for high-voltage fuse-links for motor circuit applications. IEC 60645 Electroacoustics – Audiometric equipment. IEC 60648 Method of test for coefficients of friction of plastic film and sheeting for use as electrical insulation.