Equipotential bonding involves electrically connecting metalwork so that it is at the same voltage everywhere. Exact rules for electrical installations vary by country, locality, or supplying power company. [2] Equipotential bonding is done from where the distribution wiring enters the building to incoming water and gas services.
Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.
An isolated ground (IG) (or Functional Earth (FE) in European literature) is a ground connection to a local earth electrode from equipment where the main supply uses a different earthing arrangement, one of the common earthing arrangements used with domestic mains supplies.
An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the equipment's conductive surface, for safety and functional purposes. [1] The choice of earthing system can affect the safety and electromagnetic compatibility of the installation.
The neutral conductor of a 3-phase, 4-wire system and the middle conductor of a 2- phase, 3-wire system must have at least 2 separate and distinct earth connections with a minimum of 2 different earth electrodes to have a satisfactory earth resistance; The earth electrodes must be interconnected to reduce earth resistance
A multipoint ground system is more complicated to install and maintain over the long term, and can be more expensive to install. Star topology systems can be converted to multipoint systems by installing new conductors between old existing ones. However, this should be done with care as it can inadvertently introduce noise onto signal lines during the conversion process. The noise can be ...
Faraday cages cannot block stable or slowly varying magnetic fields, such as the Earth's magnetic field (a compass will still work inside one). To a large degree, however, they shield the interior from external electromagnetic radiation if the conductor is thick enough and any holes are significantly smaller than the wavelength of the radiation.
Bonding (including main bonding, supplementary bonding and equipotential bonding) Connection made to Earth, for protective purposes, either for individual components, for other metal objects in the premises (such as gas, water, or oil piping), or for the installation (or some part of it) as a whole. Earth/ground rod