Search results
Results From The WOW.Com Content Network
Reference ranges for blood tests of plasma renin activity can be given both in mass and in international units (μIU/mL or equivalently mIU/L, improperly shown as μU/mL or U/L, confusing mcU/mL used where Greek μ not available), with the former being roughly convertible to the latter by multiplying with 11.2. [3]
The blood insulin level can be measured in international units, such as μIU/mL or in molar concentration, such as pmol/L, where 1 μIU/mL equals 6.945 pmol/L. [64] A typical blood level between meals is 8–11 μIU/mL (57–79 pmol/L).
For example, on a certain monitor, the horizontal distance between the upper limits for parathyroid hormone in pmol/L and pg/mL may be 7 cm, with the mass concentration to the right. A molar concentration of, for example, 5 pmol/L would therefore correspond to a mass concentration located 7 cm to the right in the mass diagram, that is ...
Multivitamins nutrition facts label showing that the international unit of, for example, vitamins D and E correspond to different gram values. In pharmacology, the international unit (IU) is a unit of measurement for the effect or biological activity of a substance, for the purpose of easier comparison across similar forms of substances.
Metric prefixes; Text Symbol Factor or; yotta Y 10 24: 1 000 000 000 000 000 000 000 000: zetta Z 10 21: 1 000 000 000 000 000 000 000: exa E 10 18: 1 000 000 000 000 000 000: peta P 10 15: 1 000 000 000 000 000: tera T
An insulin tolerance test (ITT) is a medical diagnostic procedure during which insulin is injected into a patient's vein, after which blood glucose is measured at regular intervals. This procedure is performed to assess pituitary function, adrenal function, insulin sensitivity , [ 1 ] [ 2 ] and sometimes for other purposes.
The cutoff normal individuals from those with primary hyperaldosteronism is significantly affected by the conditions of testing, such as posture and time of day. On average, an ARR cutoff of 23.6 ng/dL per ng/(mL·h), expressed in alternative units as 651 pmol/L per μg/(L·h), has been estimated to have a sensitivity of 97% and specificity of 94%. [2]
The glucose tolerance test was first described in 1923 by Jerome W. Conn. [4]The test was based on the previous work in 1913 by A. T. B. Jacobson in determining that carbohydrate ingestion results in blood glucose fluctuations, [5] and the premise (named the Staub-Traugott Phenomenon after its first observers H. Staub in 1921 and K. Traugott in 1922) that a normal patient fed glucose will ...