When.com Web Search

  1. Ads

    related to: masonry drive pin anchors for concrete forms 4

Search results

  1. Results From The WOW.Com Content Network
  2. Precast concrete lifting anchor system - Wikipedia

    en.wikipedia.org/wiki/Precast_concrete_lifting...

    When an anchors load resistance must consider load reduction factors, this would imply that the particular selected anchor will form a different failure crack zone. For example, the anchors depicted in figure 5, a footed anchor has the tendency to overload the concrete cover in thin wall panels, hence is more susceptible to side blow-out ...

  3. Anchor bolt - Wikipedia

    en.wikipedia.org/wiki/Anchor_bolt

    In this case, concrete base material might be undamaged. Pull-out: the anchor is pulled out from the drilled hole partially damaging the surrounding concrete. When the concrete is damaged the failure is also indicated as pull-through. Concrete cone: after reaching the load-bearing capacity a cone shape is formed.

  4. List of screw and bolt types - Wikipedia

    en.wikipedia.org/wiki/List_of_screw_and_bolt_types

    The screw itself should be drilled a minimum of 1" into the concrete to hold effectively and a maximum of 1-3/4" or the threads will wear and will lose holding power. Ideally 1-1/4" to 1-1/2" of screw thread in the concrete. [1] So for example, if a 1/2" board is being screwed onto the concrete, a 1-3/4" to 2" concrete screw should be used ...

  5. Anchor plate - Wikipedia

    en.wikipedia.org/wiki/Anchor_plate

    An anchor plate, floor plate [1] or wall washer is a large plate or washer connected to a tie rod or bolt. Anchor plates are used on exterior walls of masonry buildings, for structural reinforcement against lateral bowing. Anchor plates are made of cast iron, sometimes wrought iron or steel, and are often made in a decorative style. [2]

  6. Glossary of prestressed concrete terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_prestressed...

    [1]: 4 anchor recess A formwork blockout or recess former fitted to the edge formwork of a post-tensioned concrete member, and that creates a temporary void space external to the prestressing anchor to allow the anchor block or similar to be fitted after formwork stripping. [3]: 32 anchor set See wedge set. anchorage assembly

  7. Concrete cone failure - Wikipedia

    en.wikipedia.org/wiki/Concrete_cone_failure

    Under tension loading, the concrete capacity of a single anchor is calculated assuming an inclination between the failure surface and surface of the concrete member of about 35°. The concrete cone failure load N 0 {\displaystyle N_{0}} of a single anchor in uncracked concrete unaffected by edge influences or overlapping cones of neighboring ...