When.com Web Search

  1. Ads

    related to: air flow calculator for duct systems for homes

Search results

  1. Results From The WOW.Com Content Network
  2. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only.

  3. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  4. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  5. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...

  6. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    Balancing is the methodical regulation of system fluid flows (air or water) through the use of acceptable procedures to achieve the desired or specified design airflow or water flow. When beginning the balance of a system, you must locate the terminal with the least amount of flow in regards to the engineer's drawing. Once the "low" terminal ...

  7. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law between the airflow rate and the pressure difference across the building envelope as follows: [16] q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in m 3 h −1; C L is the air leakage coefficient expressed in m 3 h −1 Pa −n