Ad
related to: vernier caliper minimum count for water pump pressure tank cost
Search results
Results From The WOW.Com Content Network
Vernier caliper scales; main at top, vernier at bottom. It reads 3.58 ± 0.02 mm by adding 3.00 mm (left red mark) on the fixed main scale to vernier 0.58 mm (right red mark). The main scale reading is that to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales.
In the science of measurement, the least count of a measuring instrument is the smallest value in the measured quantity that can be resolved on the instrument's scale. [1] The least count is related to the precision of an instrument; an instrument that can measure smaller changes in a value relative to another instrument, has a smaller "least ...
A vernier caliper does not easily lose its calibration, but a sharp impact or accidental damage to the measuring surface in the caliper jaw can be significant enough to displace zero. [29] Digital calipers have zero set buttons, for quick recalibration. Vernier, dial and digital calipers can be used with accessories that extend their usefulness.
Vernier caliper scales; main at top, vernier at bottom. It reads 3.58 mm ± 0.02 mm by adding 3.00 mm (left red mark) on the fixed main scale to vernier 0.58 mm (right red mark). The main scale reading is the rightmost graduation that is to the left of the zero on the vernier scale.
Case 1 is an empty tank at the charging pressure P c (gauge). The total volume of the tank is V t. Case 2 is a tank in use, with the air pressure at pressure P (gauge) and a water volume of V. Referring to the diagram on the right, a pressure tank is generally pressurized when empty with a "charging pressure" P c, which is usually about 2 psi ...
When using a micrometer to set a dial bore gauge, the accuracy of the measurement will be 0.002 inches or 0.0508 millimeters. A ring gauge can be used to obtain higher accuracy at a higher cost and higher time requirement. When a dial bore gauge is set using a ring gauge, overall accuracy can be within 0.0001 inches or 0.00254 millimeter. [2]
Example Number 1: A tank with a liquid level 2 metres above the pump intake, plus the atmospheric pressure of 10 metres, minus a 2 metre friction loss into the pump (say for pipe & valve loss), minus the NPSH R curve (say 2.5 metres) of the pre-designed pump (see the manufacturers curve) = an NPSH A (available) of 7.5 metres. (not forgetting ...
The term "metering pump" is based on the application or use rather than the exact kind of pump used, although a couple types of pumps are far more suitable than most other types of pumps. [2] Although metering pumps can pump water, they are often used to pump chemicals, solutions, or other liquids.