When.com Web Search

  1. Ad

    related to: installing an erv attic

Search results

  1. Results From The WOW.Com Content Network
  2. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    The specific equipment involved may be called an Energy Recovery Ventilator, also commonly referred to simply as an ERV. An ERV is a type of air-to-air heat exchanger that transfers latent heat as well as sensible heat. Because both temperature and moisture are transferred, ERVs are described as total enthalpic devices. In contrast, a heat ...

  3. Attic fan - Wikipedia

    en.wikipedia.org/wiki/Attic_fan

    An attic fan installed underneath a roof. A powered attic ventilator, or attic fan, is a ventilation fan that regulates the heat level of a building's attic by exhausting hot air. A thermostat is used to automatically turn the fan off and on, while sometimes a manual switch is used. An attic fan can be gable mounted or roof mounted. Additional ...

  4. Sheet Metal and Air Conditioning Contractors' National ...

    en.wikipedia.org/wiki/Sheet_Metal_and_Air...

    SMACNA standards and manuals address all facets of the sheet metal industry, from duct construction and installation to indoor air quality and air pollution control, from energy recovery to roofing. SMACNA's Technical Resources Department fields several thousand technical questions annually from architects, engineers, manufacturers and ...

  5. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Fabric ducts are not rated for use in ceilings or concealed attic spaces. However, products for use in raised floor applications are available. Fabric ducting usually weighs less than other conventional ducting and will therefore put less stress on the building's structure. The lower weight allows for easier installation.

  6. Building envelope - Wikipedia

    en.wikipedia.org/wiki/Building_envelope

    The difference can be illustrated by the fact that an insulated attic floor is the primary thermal control layer between the inside of the house and the exterior while the entire roof (from the surface of the roofing material to the interior paint finish on the ceiling) is part of the building envelope.

  7. Ground-coupled heat exchanger - Wikipedia

    en.wikipedia.org/wiki/Ground-coupled_heat_exchanger

    An open system combined with energy recovery ventilation can be nearly as efficient (80-95%) as a closed loop, and ensures that entering fresh air is filtered and tempered. Combination system: This can be constructed with dampers that allow either closed or open operation, depending on fresh air ventilation requirements.

  8. Run-around coil - Wikipedia

    en.wikipedia.org/wiki/Run-around_coil

    A run-around coil installation, serving air handling units on the roof of an office building. A run-around coil is a type of energy recovery heat exchanger most often positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, to recover the heat energy. Generally, it refers ...

  9. Passive solar building design - Wikipedia

    en.wikipedia.org/wiki/Passive_solar_building_design

    Filtered energy recovery ventilation systems may be useful to eliminate undesirable humidity, dust, pollen, and microorganisms in unfiltered ventilation air. Natural convection causing rising warm air and falling cooler air can result in an uneven stratification of heat. This may cause uncomfortable variations in temperature in the upper and ...