When.com Web Search

  1. Ads

    related to: aami standards for sterilization and infection

Search results

  1. Results From The WOW.Com Content Network
  2. Association for the Advancement of Medical Instrumentation

    en.wikipedia.org/wiki/Association_for_the...

    The Association for the Advancement of Medical Instrumentation (AAMI) is an organization for advancing the development, and safe and effective use of medical technology founded in 1965 by Robert D. Hall Jr. and Robert J. Allen, President and Vice President respectively of Tech/Reps, Inc. (a medical Instrumentation marketing firm in Needham, Massachusetts).

  3. New Standard for Medtech Alternate Equipment Management (AEM)

    lite.aol.com/tech/story/0022/20250113/9330958.htm

    Today, the Association for the Advancement of Medical Instrumentation (AAMI) announces the release of an industry standard that clarifies the issue. Since the 2014 CMS Survey & Certification Group letter allowing certain AEM activities, accrediting bodies and healthcare technology management (HTM) professionals have debated over compliance.

  4. Central sterile services department - Wikipedia

    en.wikipedia.org/wiki/Central_sterile_services...

    Sterile dental instruments from hospital central supply (barcoded label indicating sterilization date, expiry date and contents). The central sterile services department (CSSD), also called sterile processing department (SPD), sterile processing, central supply department (CSD), or central supply, is an integrated place in hospitals and other health care facilities that performs sterilization ...

  5. Spaulding classification - Wikipedia

    en.wikipedia.org/wiki/Spaulding_classification

    Earle Spaulding of Temple University (Philadelphia, Pennsylvania) in a 1939 paper on disinfection of surgical instruments in a chemical solution proposed "a strategy for sterilization or disinfection of inanimate objects and surfaces based on the degree of risk involved in their use". [1]

  6. Infection prevention and control - Wikipedia

    en.wikipedia.org/wiki/Infection_prevention_and...

    The time is counted once the temperature that is needed has been reached. Steam sterilization requires four conditions in order to be efficient: adequate contact, sufficiently high temperature, correct time and sufficient moisture. [16] Sterilization using steam can also be done at a temperature of 132 C (270 F), at a double pressure. [citation ...

  7. Asepsis - Wikipedia

    en.wikipedia.org/wiki/Asepsis

    The goal of asepsis is to eliminate infection, not to achieve sterility. [1] Ideally, a surgical field is sterile, meaning it is free of all biological contaminants (e.g. fungi, bacteria, viruses), not just those that can cause disease, putrefaction, or fermentation. [1] Even in an aseptic state, a condition of sterile inflammation may develop.

  8. Sterility assurance level - Wikipedia

    en.wikipedia.org/wiki/Sterility_assurance_level

    For example, medical device manufacturers design their sterilization processes for an extremely low SAL, such as 10 −6, which is a 1 in 1,000,000 chance of a non-sterile unit. SAL also describes the killing efficacy of a sterilization process. A very effective sterilization process has a very low SAL.

  9. Autoclave - Wikipedia

    en.wikipedia.org/wiki/Autoclave

    Some computer-controlled autoclaves use an F 0 (F-nought) value to control the sterilization cycle. F 0 values are set for the number of minutes of sterilization equivalent to 121 °C (250 °F) at 103 kPa (14.9 psi) above atmospheric pressure for 15 minutes. Since exact temperature control is difficult, the temperature is monitored, and the ...