This means that all pure copper (Cu) wires (which have not been subjected to distortion of their crystalline structure etc.), irrespective of their shape and size, have the same resistivity, but a long, thin copper wire has a much larger resistance than a thick, short copper wire. Every material has its own characteristic resistivity.
As quoted in an online version of: David R. Lide (ed), CRC Handbook of Chemistry and Physics, 84th Edition.CRC Press. Boca Raton, Florida, 2003; Section 4, Properties of the Elements and Inorganic Compounds; Physical Properties of the Rare Earth Metals
A copper strip is formed into the shape of a cylinder, while it is being wrapped around an aluminum core and the edges of the copper strip are welded together. The assembly is then pulled through a die, where the cladded wire is squeezed and stretched while also improving the bonding between the copper and the aluminum core. [1]
Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...
The resistance of a given object depends primarily on two factors: what material it is made of, and its shape. For a given material, the resistance is inversely proportional to the cross-sectional area; for example, a thick copper wire has lower resistance than an otherwise-identical thin copper wire.
An example of a copper alloy conductor is cadmium copper wire, which is used for railroad electrification in North America. [5] In Britain the BPO (later Post Office Telecommunications ) used cadmium copper aerial lines with 1% cadmium for extra strength; for local lines 40 lb/mile (1.3 mm dia) and for toll lines 70 lb/mile (1.7 mm dia).
For a given material, the resistance is inversely proportional to the cross-sectional area. [1] For example, a thick copper wire has lower resistance than an otherwise-identical thin copper wire. Also, for a given material, the resistance is proportional to the length; for example, a long copper wire has higher resistance than an otherwise ...
International Annealed Copper Standard (IACS) pure =1.7×10 −8 Ω•m =58.82×10 6 Ω −1 •m −1. For main article, see: Copper in heat exchangers. The TPRC recommended values are for well annealed 99.999% pure copper with residual electrical resistivity of ρ 0 =0.000851 μΩ⋅cm. TPRC Data Series volume 1 page 81. [8]