When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. ASHRAE Handbook - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_Handbook

    Members of ASHRAE receive the current volume, in both print and CD-ROM form, each year as a basic membership benefit. An enhanced electronic version, known as ASHRAE Handbook Online is a web-based version updated annually that contains the four latest volumes as well as extra content such as calculations, demonstration videos, and spreadsheets ...

  3. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    The graphic comfort zone model is limited in applicability to conditions when the metabolic rate of occupants is 1.0-1.3 met and the humidity ratio is below 0.012 kg H 2 O/kg dry air (0.012 lb H 2 O/lb dry air). If these requirements are met and the environmental conditions inside the building fall within the indicated ranges, then compliance ...

  4. Minimum efficiency reporting value - Wikipedia

    en.wikipedia.org/wiki/Minimum_Efficiency...

    3.01.0 μm ("E2") Legionella, humidifier dust, lead dust, milled flour, auto emission particulates, nebulizer droplets Superior residential, better commercial, hospital laboratories 13–16 1.00.3 μm ("E1") Bacteria, droplet nuclei (sneeze), cooking oil, most smoke and insecticide dust, most face powder, most paint pigments Hospital and

  5. Thermal comfort - Wikipedia

    en.wikipedia.org/wiki/Thermal_comfort

    ASHRAE 55 provides a table of metabolic rates for a variety of activities. Some common values are 0.7 met for sleeping, 1.0 met for a seated and quiet position, 1.21.4 met for light activities standing, 2.0 met or more for activities that involve movement, walking, lifting heavy loads or operating machinery.

  6. Air filtration in operating rooms - Wikipedia

    en.wikipedia.org/wiki/Air_filtration_in...

    High-efficiency particulate air (HEPA) filter is at least 99.97% effective in removing particles ≥0.3 μm in diameter (as a reference, Aspergillus spores are 2.5–3.0 μm in diameter). [3] High-level HEPA filtration and increasing air changes per hour (ACH) can reduce particulate matter (PM) and bacterial concentrations in the operating room ...

  7. ASHRAE - Wikipedia

    en.wikipedia.org/wiki/ASHRAE

    ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]

  8. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]

  9. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load. These include the global coordinates of the site and the size of the structure. [1] [5]