When.com Web Search

  1. Ads

    related to: calibration procedure for calipers near me prices list

Search results

  1. Results From The WOW.Com Content Network
  2. Air Force Metrology and Calibration Program Office - Wikipedia

    en.wikipedia.org/wiki/Air_Force_Metrology_and...

    In 1968, the 2802nd Inertial Guidance and Calibration Group was inactivated and replaced by the Aerospace Guidance and Metrology Center (AGMC). The Calibration and Metrology Division was changed to the Directorate of Metrology on 8 November 1968. Newark Air Force Station was renamed Newark Air Force Base in June 1987.

  3. Vernier scale - Wikipedia

    en.wikipedia.org/wiki/Vernier_scale

    The standard for a caliper is usually a constant of 0.02 Vernier caliper scale with the normal 0.02 vernier constant, showing measurement of object at 19.44 mm to two decimal places. The use of the vernier scale is shown on a vernier caliper which measures the internal and the external diameters of an object.

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.

  5. Calipers - Wikipedia

    en.wikipedia.org/wiki/Calipers

    Oddleg calipers, Hermaphrodite calipers, or Oddleg Jennys, as pictured on the left, are generally used to scribe a line at a set distance from the edge of a workpiece. The bent leg is used to run along the workpiece edge while the scriber makes its mark at a predetermined distance, this ensures a line parallel to the edge.

  6. Micrometer (device) - Wikipedia

    en.wikipedia.org/wiki/Micrometer_(device)

    If the gauge block is known to be 0.75000 ± 0.00005 inch ("seven-fifty plus or minus fifty millionths", that is, "seven hundred fifty thou plus or minus half a tenth"), then the micrometer should measure it as 0.7500 inch. If the micrometer measures 0.7503 inch, then it is out of calibration.

  7. Weighing scale - Wikipedia

    en.wikipedia.org/wiki/Weighing_scale

    A poise adds further intricacies to the calibration procedure, since the exact mass of the poise must be adjusted to the exact lever ratio of the beam. For greater convenience in placing large and awkward loads, a platform can be floated on a cantilever beam system which brings the proportional force to a noseiron bearing; this pulls on a ...