When.com Web Search

  1. Ads

    related to: fresh air intake hvac system cost

Search results

  1. Results From The WOW.Com Content Network
  2. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    The percentage of return air made up of fresh air can usually be manipulated by adjusting the opening of this vent. Typical fresh air intake is about 10% of the total supply air. [citation needed] Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction.

  3. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    Due to their simplicity, flexibility, and easy maintenance, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams. FCUs come in various configurations, including horizontal (ceiling-mounted) and vertical (floor-mounted), and can be used in a ...

  4. Furnace (central heating) - Wikipedia

    en.wikipedia.org/wiki/Furnace_(central_heating)

    A typical installation arrangement for high-efficiency furnaces includes a fresh air intake (supply) pipe that brings fresh air from outside the home to the furnace combustion unit. Normally the fresh combustion air is routed alongside the exhaust PVC during installation and the pipes exit through a sidewall of the home in the same location.

  5. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Moreover, cooling and dehumidifying fresh ventilation air compose 20–40% of the total energy load for HVAC in hot and humid climatic regions. However, that percentage can be higher where 100% fresh air ventilation is required. This means more energy is needed to meet the fresh air requirements of the occupants.

  6. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  7. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    Fresh air fraction quantifies action of the economizer, and is defined by (Mass flow rate of fresh-air / Total air flow rate). Abbreviated faf. fresh air intake An opening through which outside air is drawn into the building. This may be to replace air in the building that has been exhausted by the ventilation system, or to provide fresh air ...

  1. Ad

    related to: fresh air intake hvac system cost