When.com Web Search

  1. Ads

    related to: transformer through fault current calculator spreadsheet pdf template file

Search results

  1. Results From The WOW.Com Content Network
  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The resistance path is the total resistance back through the supply transformer; to measure this an engineer will use an "earth fault loop impedance meter". The application of a low voltage allows a small current to pass from the socket back through earth to the supply transformer and distribution board.

  3. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    Condition monitoring of transformers in electrical engineering is the process of acquiring and processing data related to various parameters of transformers to determine their state of quality and predict their failure. This is done by observing the deviation of the transformer parameters from their expected values.

  4. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...

  5. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    With negligible current in the neutral under normal conditions, an undersized (unable to carry a continuous fault load) transformer may be used only as short-time rating is required, provided the defective load will be automatically disconnected in a fault condition. The transformer's impedance should not be too low for desired maximum fault ...

  6. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    Since the secondary of the transformer is open, the primary draws only no-load current, which will have some copper loss. This no-load current is very small and because the copper loss in the primary is proportional to the square of this current, it is negligible. There is no copper loss in the secondary because there is no secondary current. [1]

  7. Fault tree analysis - Wikipedia

    en.wikipedia.org/wiki/Fault_tree_analysis

    A fault tree diagram. Fault tree analysis (FTA) is a type of failure analysis in which an undesired state of a system is examined. This analysis method is mainly used in safety engineering and reliability engineering to understand how systems can fail, to identify the best ways to reduce risk and to determine (or get a feeling for) event rates of a safety accident or a particular system level ...

  8. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    Provide a source of ground fault current during line-to-ground faults. Permit the connection of phase-to-neutral loads when desired. [2] Earthing transformer with a zig-zag. Grounding transformers most commonly incorporate a single winding transformer with a zigzag winding configuration, but may also be created with a (rare case) delta-wye ...

  9. Steinmetz's equation - Wikipedia

    en.wikipedia.org/wiki/Steinmetz's_equation

    The equation is used mainly to calculate core losses in ferromagnetic magnetic cores used in electric motors, generators, transformers and inductors excited by sinusoidal current. Core losses are an economically important source of inefficiency in alternating current (AC) electric power grids and appliances.