When.com Web Search

  1. Ads

    related to: calculate maximum available fault current labels for water tanks

Search results

  1. Results From The WOW.Com Content Network
  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power outlet can rise relative to the local earth (concrete floor, water pipe etc.) to a ...

  3. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    When Q2 turns on, it removes the base current from Q1, thereby reducing the collector current of Q1, which is nearly the load current. Thus, R sens fixes the maximum current to a value given by 0.65/R sens. For example, if R sens = 0.33 Ω, the current is limited to about 2 A even if R load becomes a short (and V o becomes zero).

  4. Eurocode 8: Design of structures for earthquake resistance

    en.wikipedia.org/wiki/Eurocode_8:_Design_of...

    In EN 1998-4, principles and application rules for the seismic design of the structural aspects of facilities composed of above-ground and buried pipeline systems and of storage tanks of different types and uses, as well as for independent items, such as for example single water towers serving a specific purpose or groups of silos enclosing ...

  5. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    The current breaking capacity corresponds to a certain voltage, so an electrical apparatus may have more than one breaking capacity current, according to the actual operating voltage. Breaking current may be stated in terms of the total current or just in terms of the alternating-current (symmetrical) component.

  6. Arc flash - Wikipedia

    en.wikipedia.org/wiki/Arc_flash

    IEEE 1584 provides a guide to perform these calculations given that the maximum fault current, duration of faults, and other general equipment information is known. Once the incident energy is calculated the appropriate ensemble of PPE that offers protection greater than the energy available can be selected.

  7. ASME Boiler and Pressure Vessel Code - Wikipedia

    en.wikipedia.org/wiki/ASME_Boiler_and_Pressure...

    Division 1 - Rules for Inspection and Testing of Components of Light-Water-Cooled Plants; Division 2 - Requirements for Reliability and Integrity Management (RIM) Programs for Nuclear Power Plants; ASME BPVC Section XII - Rules for the Construction and Continued Service of Transport Tanks; ASME BPVC Section XIII - Rules for Overpressure Protection