A reagent, termed the titrant or titrator, [2] is prepared as a standard solution of known concentration and volume. The titrant reacts with a solution of analyte (which may also be termed the titrand [3]) to determine the analyte's concentration. The volume of titrant that reacted with the analyte is termed the titration volume.
Differences in the temperature between the titrant and the titrand; Evaporative losses from the surface of the rapidly mixed fluid; Heats of solution when the titrant solvent is mixed with the analyte solvent; Heat introduced by the mechanical action of stirring (minor influence); and; Heat produced by the thermistor itself (very minor influence).
In analytical chemistry, a standard solution (titrant or titrator) is a solution containing an accurately known concentration. Standard solutions are generally prepared by dissolving a solute of known mass into a solvent to a precise volume, or by diluting a solution of known concentration with more solvent. [ 1 ]
After enough titrant has been added to react completely with the analyte, the excess titrant may itself be reduced at the working electrode. Since this is a different species with different diffusion characteristics (and different half-reaction ), the slope of current versus added titrant will have a different slope after the equivalence point.
The volumetric titration is based on the same principles as the coulometric titration, except that the anode solution above now is used as the titrant solution. The titrant consists of an alcohol (ROH), base (B), SO 2 and a known concentration of I 2. Pyridine has been used as the base in this case. One mole of I 2 is consumed for each mole of ...
E cell is recorded at intervals as the titrant is added. A graph of potential against volume added can be drawn and the end point of the reaction is halfway between the jump in voltage. E cell depends on the concentration of the interested ions with which the indicator electrode is in contact. For example, the electrode reaction may be
The electrochemical generation of a titrant is much more sensitive and can be much more accurately controlled than the mechanical addition of titrant using a burette drive. For example, a constant current flow of 10 μA for 100 ms is easily generated and corresponds to about 10 micrograms of titrant.
Depending on whether the reaction between the titrant and analyte is exothermic or endothermic, the temperature will either rise or fall during the titration. When all analyte has been consumed by reaction with the titrant, a change in the rate of temperature increase or decrease reveals the equivalence point and an inflection in the ...